m1s_ups_control_mirror_test/service.py

170 lines
4.4 KiB
Python
Raw Normal View History

2024-04-29 07:04:45 +00:00
import serial
import os
import time
import subprocess
2024-07-13 16:22:47 +00:00
import logging
import threading
from logging.handlers import RotatingFileHandler, TimedRotatingFileHandler
import signal
2024-04-29 07:04:45 +00:00
2024-07-13 16:22:47 +00:00
class GracefulKiller:
kill_now = False
def __init__(self):
signal.signal(signal.SIGINT, self.exit_gracefully)
signal.signal(signal.SIGTERM, self.exit_gracefully)
def exit_gracefully(self, signum, frame):
self.kill_now = True
log.info('UPS service is being stopped')
class UPS:
def __init__(self):
ups_loc = subprocess.check_output(['sudo','/bin/bash','kill.sh'])
ups_loc = ups_loc.decode("UTF-8")
ups_loc = ups_loc.replace("\n", "")
self.ser = serial.Serial(ups_loc, 9600)
def get_firmver(self):
return self.__get('@Fx#').replace("F","").replace("-",".")
def get_curvol(self):
return self.__get('@V0#').replace("V","")
def get_chargestat(self):
a = self.__get('@C0#').replace("","")
if a == "CF0C0":
return "err"
elif a == "CF1C0":
return "chg"
elif a == "CF0C1":
return "full"
elif a == "CF1C1":
return "dch"
def shutdown(self):
self.__get('@Px#')
def __get(self,a):
a = bytes(a, 'utf-8')
self.ser.write(a)
a = self.ser.readline().decode("UTF-8")
a = a.replace("\n", "")
a = a.replace("\r", "")
a = a.replace("#", "")
a = a.replace("@", "")
return(a)
class Logger:
def __init__(self):
self.logger = logging.getLogger()
self.logger.setLevel(logging.INFO)
formatter = logging.Formatter('%(asctime)s %(levelname)s: %(message)s', datefmt='%Z %Y:%m:%d %H:%M:%S')
file_handler = RotatingFileHandler('./log/ups.log', maxBytes=1024*1024*10, backupCount=10)
file_handler.setFormatter(formatter)
consoleHandler = logging.StreamHandler()
consoleHandler.setFormatter(formatter)
self.logger.addHandler(file_handler)
self.logger.addHandler(consoleHandler)
2024-04-29 07:04:45 +00:00
2024-07-13 16:22:47 +00:00
def debug(self,message):
self.logger.debug(message)
def info(self,message):
self.logger.info(message)
def warn(self,message):
self.logger.warning(message)
def error(self,message):
self.logger.error(message)
def crit(self,message):
self.logger.critical(message)
killer = GracefulKiller()
log = Logger()
log.info('UPS service is starting')
ups = UPS()
try:
import pwmio
import board
asfdafsd
log.info('gpio module import success')
except:
log.warn('gpio module import failed buzzer not working')
log.warn('Create a dummy class')
#Dummy class
class Alarm:
def __init__(self):
pass
def on(self):
pass
def off(self):
pass
else:
try:
class Alarm:
def __init__(self):
self.piezo = pwmio.PWMOut(board.D15, variable_frequency=True)
self.piezo.duty_cycle = 0
self.piezo.frequency = 523
def on(self):
self.piezo.duty_cycle = 50000
def off(self):
self.piezo.duty_cycle = 0
except:
log.crit('gpio pin assignment failure')
log.warn('Create a dummy class')
#Dummy class
class Alarm:
def __init__(self):
pass
def on(self):
pass
def off(self):
pass
2024-07-13 16:22:47 +00:00
buz = Alarm()
buz.on()
log.info('UPS service started successfully')
log.info(f"UPS Firmware Ver {ups.get_firmver()}")
time.sleep(0.3)
buz.off()
while not killer.kill_now:
ps = ups.get_chargestat()
if ps == "full":
log.info("AC power active")
elif ps == "chg":
log.info('AC power restored Charging')
elif ps == "dch":
2024-07-13 16:39:53 +00:00
buz.on()
2024-07-13 16:22:47 +00:00
log.warn('AC power loss')
pw = int(ups.get_curvol())
if pw <= 3500:
2024-07-13 16:48:24 +00:00
log.crit('battery is too low Shut down system')
2024-07-13 16:22:47 +00:00
ups.shutdown()
2024-04-29 07:04:45 +00:00
os.system("shutdown now")
2024-07-13 16:22:47 +00:00
elif pw <= 3650:
log.crit('battery is too low')
2024-07-13 16:45:25 +00:00
elif pw <= 3800:
log.warn('battery is low')
2024-07-13 16:22:47 +00:00
elif ps == "err":
log.crit('UPS hardware error detect')
log.info("Current Voltage "+ups.get_curvol()+"mV")
time.sleep(0.5)
2024-07-13 16:39:53 +00:00
buz.off()
time.sleep(0.5)
buz.off()
2024-07-13 16:22:47 +00:00
log.info('UPS service stopped successfully')